SSP 390 The 7-speed Double-clutch Gearbox 0AM
Actuators
Clutch actuator solenoid valves
Valve 3 in gear train half 1 N435, valve 3 in gear train half 2 N439
The clutch actuator solenoid valves are located in the mechatronic unit's hydraulic module. They are actuated by the electronic gearbox control unit. They are used to control the oil volume for actuating the clutches.
- Solenoid valve N435 controls the oil volume for clutch K1
- Solenoid valve N439 controls the oil volume for clutch K2

Effects of signal failure
If one of the solenoid valves fails, the corresponding gear train half is shut off.
Gear train half pressure control valves
Valve 4 in gear train half 1 N436, valve 4 in gear train half 2 N440
Both valves are solenoid valves, and are located in the mechatronic unit's hydraulic module. Valve 4 in gear train half 1 controls the hydraulic oil pressure to the gear selectors and to the clutch actuator in gear train half 1.
Gear train half 1 is used to shift gears 1, 3, 5 and 7. Valve 4 in gear train half 2 controls the hydraulic oil pressure to the gear selectors and to the clutch actuator in gear train half 2.

Effects of signal failure
If one of the solenoid valves fails, the corresponding gear train half is shut off, and only the gears assigned to the other gear train half can be engaged.
Gear selector solenoid valves
Valve 1 in gear train half 1 N433, valve 2 in gear train half 1 N434, valve 1 in gear train half 2 N437, valve 2 in gear train half 2 N438
The gear selector solenoid valves are located in the mechatronic unit's hydraulic module. They are used by the gearbox control unit to control the oil volume to the gear selectors and therefore for changing gears.
- N433 gears 1 and 3, gear train half 1
- N434 gears 5 and 7, gear train half 1
- N437 gears 4 and 2, gear train half 2
- N438 gears 6 and R, gear train half 2

Effects of signal failure
If one of the solenoid valves fails, the corresponding gear train half is shut off.
Motor for hydraulic pump V401
The motor for the hydraulic pump is integrated into the mechatronic unit's hydraulic module. It is actuated by the gearbox control unit subject to requirements.
The control unit shuts the motor off when the hydraulic pressure in the system has reached 60 bar, and switches it on again when the pressure has fallen to 40 bar.

Effects of signal failure
If the motor cannot be actuated, the hydraulic pressure drops and the clutches open independently due to the pressure plates' spring force.