1.6 TDI CR engine (EA189) · Cooling · Cooling system/coolant

Draining and adding coolant

⇒ 1.3.1 Draining coolant

⇒ 1.3.2 Filling with coolant

1.3.1 Draining coolant

On a warm engine, the cooling system is under high pressure.

Cover filler cap on expansion tank with a cloth and open carefully to release pressure.

Draining and adding coolant: drawing 1
  • Open filler cap -1- on coolant expansion tank.
  • Remove noise insulation:

    Polo ⇒ General body repairs, exterior; Rep. gr. 50; Noise insulation; Assembly overview - noise insulation

  • Place drip tray - VAS 6208- beneath engine.

Polo

Draining and adding coolant: drawing 2
  • Pull off coolant hoses -2- from coolant circulation pump 2 - V178-.
Draining and adding coolant: drawing 3
  • Disconnect lower coolant hose from radiator, loosen hose clamp -arrow- to do so and then drain off coolant.
  • Open clamp -arrow- for this.
Draining and adding coolant: drawing 4
  • Disconnect lower coolant hose on right from radiator, loosen hose clamp -arrow- to do so and then drain off coolant.
  • Disconnect coolant hose from oil filter housing, loosen hose clamp -arrow- to do so and then drain off remaining coolant.

Continuation for all vehicles

Draining and adding coolant: drawing 5
  • To drain coolant from engine, also remove coolant hose from engine oil cooler -arrow-.

1.3.2 Filling with coolant

If the coolant has been drained off, the cooling system must be filled using the cooling system charge unit - VAS 6096- ⇒ 1.3.2 Filling with coolant.

Recommended mixture ratios:

  • Coolant additive (40 %) and distilled water (60 %) for frost protection to -25 °C
  • Coolant additive (50%) and distilled water (50%) for frost protection to -35°C
  • Coolant additive (60 %) and distilled water (40 %) for frost protection to -40 °C

Installing

  • Reconnect coolant hoses.
  • Install noise insulation:

    Polo ⇒ General body repairs, exterior; Rep. gr. 50; Noise insulation; Assembly overview - noise insulation

With cooling system charge unit - VAS 6096- :

  • Screw adapter for cooling system tester - V.A.G 1274/8- onto expansion tank.
  • Fill coolant circuit using cooling system charge unit - VAS 6096-.

Operating instructions for cooling system charge unit - VAS 6096- are enclosed with unit.

Draining and adding coolant: drawing 6
  • Fill tank of cooling system charge unit - VAS 6096- with at least 8 litres of pre-mixed coolant in correct mixture ratio.

Without cooling system charge unit - VAS 6096- :

Draining and adding coolant: drawing 7
  • Slowly fill coolant to upper marking of shaded field on expansion tank.
  • Fit expansion tank cap.
  • Start engine and maintain an engine speed of about 2,000 rpm for about 3 minutes.
  • Then run engine at idling speed until radiator fan cuts in.
  • Check coolant level and top up as needed. When engine is at normal operating temperature, the coolant level must be at the upper mark; when engine is cold, in the middle of the shaded field.