1.4 TSI engine (EA111) · Turbocharging/supercharging · Exhaust turbocharger
Checking vacuum unit for turbocharger
Special tools and workshop equipment required

- Hand operated vacuum pump - VAS 6213-

- Check retaining clip -1- is seated correctly on vacuum unit linkage.
Securing nut -2- must be locked with sealing paint.

- Pull hose -arrow- off vacuum unit.

- Fit hose -2- onto vacuum unit connection.
- Push sliding ring -1- on hand vacuum pump - VAS 6213- to stop in direction of -arrow-.

- Operate hand vacuum pump - VAS 6213- until a pressure of 700 mbar is displayed on pressure gauge.
Linkage of vacuum unit -1- must move in direction of -arrow-.
If pressure of 700 mbar is displayed:
Vacuum unit is OK.
If pressure drops abruptly:
- Renew vacuum unit ⇒ 1.2 Removing and installing turbocharger.