1.2 TDI CR engine (EA189) · Exhaust system · Exhaust gas recirculation
Checking changeover for exhaust gas recirculation cooler
Special tools and workshop equipment required

- Hand operated vacuum pump - VAS 6213-
Procedure
- Remove noise insulation ⇒ General body repairs, exterior ⇒ Rep. gr. 50.

- Unscrew bolts -1- and remove cover for right drive shaft.
- Remove heat shield sleeve.


- Pull vacuum hose off vacuum unit and connect hand vacuum pump - VAS 6213- instead.
- Use hand vacuum pump to generate vacuum.
- The linkage of the exhaust gas recirculation cooler changeover must move -arrows-.
If linkage does not move or only moves in jerks:
- Vacuum actuator is defective.
- Changeover flap for exhaust gas recirculation is tight.
- Replace exhaust gas recirculation cooler ⇒ 3.1 Assembly overview - exhaust gas recirculation.