# Actuators – SSP 308 Direct Shift Gearbox 02E

> Pressure control valves N215 to N218, N233 and N371 and solenoid valves N88 to N92: their task and the effects of a failure.

- Web page: https://catalog.polo.blue/self-study/ssp-308-direct-shift-gearbox-dq250-02e/actuators/
- Original document (PDF): https://cdn.polo.blue/files/SSP-308-direct-shift-gearbox-DQ250-02E.pdf

## Pressure control valve 3 N217 (main pressure valve)

Main pressure valve 3 can be found in the mechatronics electro-hydraulic control unit. It is a modulation valve. The main pressure in the mechatronics hydraulic system is regulated by means of this valve. The most important factor for calculation of main pressure is the actual clutch pressure, which is dependent on engine torque.

The engine temperature and engine speed are used to correct the main pressure. The control unit continually adapts the main pressure to the current operating conditions.

![Pressure control valve 3 N217 (main pressure valve)](https://catalog.polo.blue/instructions/ssp-308/a7c05295be82ab3b.webp)

### Effects of signal failure

In the event of pressure valve failure, the system works under maximum pressure. This can lead to increased fuel consumption and gear selection noises.

## Pressure control valve 1 N215 and pressure control valve 2 N216 (clutch valves)

The pressure control valves N215 and N216 are located in the mechatronics electro-hydraulic control unit. They are modulation valves and generate the control pressure for the multi-plate clutches – pressure control valve N215 controls multi-plate clutch K1 and pressure control valve N216 controls multi-plate clutch K2.

The basis for calculation of clutch pressure is the current engine torque. The control unit adapts the clutch pressure to the current friction variable of the multi-plate clutches.

![Pressure control valve 1 N215 and pressure control valve 2 N216 (clutch valves)](https://catalog.polo.blue/instructions/ssp-308/3b755247d9be87ae.webp)

### Effects of signal failure

In the event of pressure valve failure, the affected gearbox section is isolated. This fault will be displayed in the dash panel insert.

## Pressure control valve 4 N218 (cooling oil valve)

Pressure control valve N218 can be found in the electro-hydraulic control unit. It is a modulation valve and it controls the volume of cooling oil via an hydraulic slide valve. The control unit uses the signal from the multi-plate clutch oil temperature sender G509 to control this valve.

![Pressure control valve 4 N218 (cooling oil valve)](https://catalog.polo.blue/instructions/ssp-308/a47d208b504bec57.webp)

### Effects of signal failure

If the pressure valve cannot be actuated, the maximum volume of cooling oil will flow through the multi-plate clutches. This can result in gear change difficulties at cold ambient temperatures and excessive fuel consumption.

## Solenoid valves 1 N88, 2 N89, 3 N90 and 4 N91 (gear actuator valves)

All four solenoid valves can be found in the mechatronics electro-hydraulic control unit. They are "yes/no" valves. They control the oil pressure to all gear actuators via the multiplexer slide valve. The solenoid valves are in the closed position, unless energised, and oil pressure is thereby prevented from reaching the gear actuators.

Solenoid valve 1 N88 controls oil pressure to select 1st and 5th gear. Solenoid valve 2 N89 controls oil pressure to select 3rd and neutral gear. Solenoid valve 3 N90 controls oil pressure to select 2nd and 6th gear. Solenoid valve 4 N91 controls oil pressure to select 4th and reverse gear.

![Solenoid valves 1 N88, 2 N89, 3 N90 and 4 N91 (gear actuator valves)](https://catalog.polo.blue/instructions/ssp-308/46909823deedafa9.webp)

### Effects of signal failure

In the event of solenoid valve failure, the relevant gearbox section, in which the gear actuator can be found, will be isolated. The vehicle can only be driven in 1st and 3rd or in 2nd gear.

## Solenoid valve 5 N92 (multiplexer valve)

Solenoid valve 5 N92 can be found in the mechatronics electro-hydraulic control unit. It controls the multiplexer in the hydraulic control unit.

When the solenoid valve is activated, 2nd, 4th and 6th gears can be selected. When the solenoid is inactive, 1st, 3rd, 5th and reverse gears can be selected.

![Solenoid valve 5 N92 (multiplexer valve)](https://catalog.polo.blue/instructions/ssp-308/0365224e34bc1bc7.webp)

### Effects of signal failure

The multiplexer valve will remain in the rest position. It can no longer be actuated by oil pressure. Incorrect gears could be selected. There is also a risk of the vehicle breaking down.

## Pressure control valve 5 N233 and pressure control valve 6 N371 (safety valves)

Pressure control valves N233 and N371 are housed in the mechatronics hydraulic module. They are modulation valves. They control the safety slide valves in the mechatronics valve chest. The safety slide valves isolate hydraulic pressure in the relevant gearbox section affected by the safety related fault.

Pressure control valve 5 N233 controls the safety slide valve for gearbox section 1. Pressure control valve 6 N371 controls the safety slide valve for gearbox section 2.

![Pressure control valve 5 N233 and pressure control valve 6 N371 (safety valves)](https://catalog.polo.blue/instructions/ssp-308/7475f888b27480bf.webp)

### Effects of signal failure

In the event of pressure control valve failure, gears can no longer be selected in the affected gearbox section. If gearbox section 1 fails, the vehicle can only be driven in 2nd gear. If gearbox section 2 fails, the vehicle can only be driven in 1st and 3rd gears.