# 4.4 Checking exhaust gas recirculation cooler for leaks – 1.6 TDI CR engine (EA189)

> VW Polo 6R, step by step: checking exhaust gas recirculation cooler for leaks, 1.6 TDI – 20 steps, special tool V.A.G 1687 and 11 drawings.

- Web page: https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/26-exhaust-system/checking-exhaust-gas-recirculation-cooler-leaks/
- Original document: https://cdn.polo.blue/files/16-tdi-cr-engine-cayacaybcayc-workshop-manual-2019.pdf
- 26 – Exhaust system, [1.6 TDI CR engine (EA189)](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/index.md)
- Previous procedure: [4.3 Removing and installing exhaust gas recirculation cooler](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/26-exhaust-system/removing-installing-exhaust-gas-recirculation-cooler/index.md)
- Next procedure: [4.5 Cleaning exhaust gas recirculation system](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/26-exhaust-system/cleaning-exhaust-gas-recirculation-system/index.md)

> **Note**
>
> A pressure of 0.8 bar is applied to the exhaust side of the exhaust gas recirculation cooler. While so, the pressure in the cooling system is measured.

Special tools and workshop equipment required

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/a526f3bf0edb665a.webp)

- Charge air system tester - V.A.G 1687-
- Adapter - V.A.G 1687/11-
- Adapter - V.A.G 1687/15- for exhaust pipes of 60 mm and 65 mm in diameter
- Adapter - V.A.G 1687/16- for exhaust pipes of 55 mm in diameter

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/13a3514d19e0166d.webp)

- Y-branch - VAS 691 005/1-
- Test adapter - VAS 691 005/5-

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/dd52d183b4bdadde.webp)

- Turbocharger tester - V.A.G 1397A- 

Test specification:

- Coolant temperature must be at least 40 °C.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/3b14fefc9c5ad70e.webp)

Connecting turbocharger tester - V.A.G 1397A- :

- Screw adapter - VAS 691 005/5- onto coolant expansion tank.
- Fit Y-branch - VAS 691 005/1- onto adapter - VAS 691 005/5-.
- Close valve -1- for connection »C«, and open valve -2- for connection »A«.
- Connect hose from connection »A« of Y-branch to connection »II« of turbocharger tester - V.A.G 1397A-.
- Set turbocharger tester - V.A.G 1397A- to switch position »II« (gauge pressure measurement), and switch it on. The setting »II« must be visible.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/634b196baa1b525d.webp)

Connecting charge air system tester - V.A.G 1687- :

- If fitted, unclip wire to exhaust flap control unit -1-.
- Loosen clamp -2- on exhaust pipe, and push it towards rear.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/c34b3fb1db7a1a8a.webp)

- On vehicles without a tunnel cross-piece, use a tensioning strap -2- to tie up exhaust pipe -1-.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/fedd6d4afa4cb672.webp)

- Connect adapter - V.A.G 1687/11- with hose -A- to exhaust pipe (engine side). Secure hose with hose clips.
  Use hose -A- for exhaust pipes of 55 mm in diameter = hose - V.A.G 1687/16-.
  Use hose -A- for exhaust pipes of 60 mm and 65 mm in diameter = hose - V.A.G 1687/15-.
- Connect charge air system tester - V.A.G 1687- to adapter - V.A.G 1687/11-.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/041899fa623516cc.webp)

Prepare charge air system tester - V.A.G 1687- as follows:

- Completely unscrew pressure regulating valve -2-, close valves -3- and -4-.

- To turn pressure regulating valve -2-, rotary knob must be pulled upwards.

- Apply compressed air -1- to charge air system tester - V.A.G 1687-.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/3bd82b88cbf23677.webp)

- Open valve -3-.
- Adjust pressure to 0.8 bar with pressure control valve -2-.
- Open valve -4- and wait until test circuit is full. If necessary, adjust pressure to 0.8 bar.

> **Note**
>
> A small amount of air escapes through the valves and enters the engine. Therefore a holding pressure test is not possible.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/ba92ab2ca372eb73.webp)

Reading turbocharger tester - V.A.G 1397A- :

- Observe turbocharger tester for approx. 5 minutes.
- The pressure indicated on the turbocharger tester must not exceed 0.025 bar.

- If the pressure on the turbocharger tester rises above 0.025 bar, compressed air is leaking from the exhaust side into the cooling system. The exhaust gas recirculation cooler has a leak. Renew exhaust gas recirculation cooler.

> **Note**
>
> When coolant cools down, a vacuum may build up. The vacuum is indicated by a »minus« symbol on the turbocharger tester. Values preceded by a »minus« symbol do not indicate a leak! If you are uncertain, equalise the pressure in the cooling system and repeat the test.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/36f5100255d8cd56.webp)

Cleaning Y-branch - VAS 691 005/1- :

> **Note**
>
> After the leakage test has been completed, the Y-branch - VAS 691 005/1- must be cleaned and any moisture which may have entered must be removed.

- Insert cleaning nozzle -D- into hose on connection -A- of Y junction.
- Fit adapter - VAS 691 005/5- onto hose of connection -B-.
- Fit compressed air hose to connection -C-.