# 2.4 Checking charge air system for leaks – 1.6 TDI CR engine (EA189)

> Checking charge air system for leaks, 1.6 TDI on the VW Polo 6R: 9 steps, special tools V.A.G 1687 and V.A.G 1687/10 and 5 drawings.

- Web page: https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/21-turbocharging-supercharging/checking-charge-air-system-for-leaks/
- Original document: https://cdn.polo.blue/files/16-tdi-cr-engine-cayacaybcayc-workshop-manual-2019.pdf
- 21 – Turbocharging/supercharging, [1.6 TDI CR engine (EA189)](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/index.md)
- Previous procedure: [2.3 Assembly overview – charge-air hose connections](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/21-turbocharging-supercharging/assembly-overview-charge-air-hose-connections/index.md)
- Next procedure: [1.1 Schematic overview – fuel system](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/23-mixture-preparation-injection/schematic-overview-fuel-system/index.md)

Special tools and workshop equipment required

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/92b5692e1abb3cf4.webp)

- Charge air system tester - V.A.G 1687-
- Adapter - V.A.G 1687/10-

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/5c44a225d91c808e.webp)

- Remove intake hose -1- from air filter.
- Insert adapter - 1687/10- in intake hose -1- and secure with clip.

Prepare charge air system tester - V.A.G 1687- as follows: 

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/041899fa623516cc.webp)

- Unscrew pressure regulating valve -2- and close valves -3- and -4-.

> **Note**
>
> To turn pressure regulating valve -2-, rotary knob must be pulled upwards.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/cc972ebd174f4021.webp)

- Connect charge air system tester - V.A.G 1687- to adapter - 1687/10- as shown.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea189-16-tdi-cr/041899fa623516cc.webp)

- Connect compressed air hose -1- (compressed air source) to charge air system tester - V.A.G 1687-.

> **Note**
>
> If there is water in the sight glass, drain at water drain screw -6-.

- Open valve -3-.
- Adjust pressure to 0.5 bar with pressure regulating valve -2-.

> **Caution**
>
> The pressure must not exceed 0.5 bar. If the pressure is too high this can cause damage to the engine.

- Open valve -4- and wait until the test circuit is filled. If necessary readjust pressure to 0.5 bar.
- Check the charge air system for leaks as follows:

- by listening
- by feeling
- with leak detector spray
- or with the ultrasonic tester - V.A.G 1842-.

> **Note**
>
> - Slight leaks on the intake side of turbocharger are permissible, as the intake hoses are not designed for high-pressure.
> - A small amount of air escapes through the valves and enters the engine. Therefore a holding pressure test is not possible.
> - Ultrasonic tester - V.A.G 1842- ⇒ operating instructions
> - Depressurise test circuit by detaching coupling from adapter - 1687/10- before removing adapter.