# 2.5 Safety precautions when working on exhaust system – 1.6 TDI CR engine (EA189)

> VW Polo 6R (Safety information), step by step: safety precautions when working on exhaust system, 1.6 TDI – 3 steps.

- Web page: https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/00-technical-data/safety-precautions-when-working-on-exhaust-system/
- Original document: https://cdn.polo.blue/files/16-tdi-cr-engine-cayacaybcayc-workshop-manual-2019.pdf
- 00 – Technical data, [1.6 TDI CR engine (EA189)](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/index.md)
- Previous procedure: [2.4 Safety precautions when working on the cooling system](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/00-technical-data/safety-precautions-when-working-cooling-system/index.md)
- Next procedure: [3.1 Rules for cleanliness](https://catalog.polo.blue/repair-manuals/engine-1-6-tdi-cr-ea189/00-technical-data/rules-for-cleanliness/index.md)

Risk of poisoning due to chemical substances

Exhaust gas temperature senders may contain chemical substances. There is a risk of poisoning or injuries to respiratory system.

- Never open an exhaust gas temperature sender by cutting, sawing or any other means.

Risk of injury due to hot condensate and particles in the exhaust system.

The exhaust system could contain hot condensate and/or particles. There is a risk of injury to the eyes, skin and respiratory system, as well as poisoning.

- Always wear protective gloves and eye protection when cutting the exhaust system.
- When cutting, use an extraction system or otherwise ensure sufficient ventilation.

> **Caution**
>
> Risk of damage to flexible joint.
>
> - Do not allow the flexible joint to kink by more than 10°.
> - Install flexible joint so that it is not under tension.
> - Do not damage wire mesh on decoupling element.