# 2.4 Checking charge air system for leaks – 1.4 TSI engine (EA211)

> Checking charge air system for leaks on the VW Polo 6R/6C: 12 steps, special tool V.A.G 1687 and 4 drawings.

- Web page: https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/21-turbocharging-supercharging/checking-charge-air-system-for-leaks/
- Original document: https://cdn.polo.blue/files/engine-CPTA-CZCA-CZEA-EA211-eng.pdf
- 21 – Turbocharging/supercharging, [1.4 TSI engine (EA211)](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/index.md)
- Previous procedure: [2.3 Removing and installing charge pressure sender GX26](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/21-turbocharging-supercharging/removing-and-installing-charge-pressure-sender-gx26/index.md)
- Next procedure: [2.5 Removing and installing air intake pipe](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/21-turbocharging-supercharging/removing-and-installing-air-intake-pipe/index.md)

Special tools and workshop equipment required

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/314640471cdd3889.webp)

- Charge air system tester - V.A.G 1687-

**Procedure**

- Remove resonator for intake air [⇒ 3.3 Removing and installing resonator for intake air](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/24-mixture-preparation-injection/air-filter/#t315-478).

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/ba2cb94379e833c1.webp)

- Press release tabs, and disconnect hose -1- for activated charcoal filter.

> **Note**
>
> Risk of chemical damage to coolant pump seal from oil ingress between coolant pump and cylinder head.

- Cover coolant pump with a cloth to collect any escaping oil.
- Seal open connection of turbocharger using a suitable plug from engine bung set - VAS 6122-.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/13f92e3a760c7150.webp)

- Connect adapter - V.A.G 1687/15- with adapter -V.A.G 1687/11- to turbocharger.
- Connect hose -1- of charge air system tester -V.A.G 1687- to adapter.

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/041899fa623516cc.webp)

Prepare charge air system tester - V.A.G 1687- as follows:

- Completely unscrew pressure regulating valve -2-, close valves -3- and -4-.

- To turn the pressure regulating valve -2- the knob must be pulled upwards.

- Connect charge air system tester - V.A.G 1687- to compressed air -1- via commercial adapter.

> **Note**
>
> If there is water in inspection glass, drain via drain screw -6-.

- Open valve -3-.

Risk of damage to engine

Risk of damage because pressure is set too high.

The pressure must not exceed 0.5 bar.

- Adjust pressure to 0.5 bar with pressure control valve -2-.
- Open valve -4- and wait until test circuit is full. If necessary, adjust pressure to 0.5 bar.
- Check charge air system for leaks by hearing, touching, with commercially available leak detector spray or using ultrasonic tester - V.A.G 1842-.

> **Note**
>
> - A small amount of air escapes through the valves and enters the engine. Therefore a holding pressure test is not possible.
> - For information on how to use the ultrasonic tester - V.A.G 1842- refer to respective ⇒ operating manual.
> - Before removing the adapter, release pressure in the test circuit by pulling off hose coupling.

**Installing**

Assemble in reverse order of dismantling. The following should be observed:

> **Note**
>
> Renew seal and O-rings.