# 4 Inlet and exhaust valves – 1.4 TSI engine (EA211)

> Inlet and exhaust valves on the VW Polo 6R/6C: 6 steps, special tools VW 387 and VAS 6079 and 4 drawings. Never rework the inlet and exhaust valves.

- Web page: https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/15-cylinder-head-valve-gear/inlet-and-exhaust-valves/
- Original document: https://cdn.polo.blue/files/engine-CPTA-CZCA-CZEA-EA211-eng.pdf
- 15 – Cylinder head, valve gear, [1.4 TSI engine (EA211)](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/index.md)
- Previous procedure: [3.8 Removing and installing cam actuators](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/15-cylinder-head-valve-gear/removing-and-installing-cam-actuators/index.md)
- Next procedure: [1.1 Assembly overview – sump/oil pump](https://catalog.polo.blue/repair-manuals/engine-1-4-tsi-ea211/17-lubrication/assembly-overview-sump-oil-pump/index.md)

## 4.1 Checking valve guides

Special tools and workshop equipment required

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/ff52267ab2677eb6.webp)

- Universal dial gauge bracket - VW 387-

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/e1fdac834d48fe7c.webp)

- Dial gauge - VAS 6079-

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/e2dc6ea18951d279.webp)

**Test sequence**

- Insert valve in guide. Valve stem end must be flush with guide. On account of differing stem diameters, only use inlet valve in inlet valve guide and exhaust valve in exhaust valve guide.
- Determine rock.

- Wear limit: 0.5 mm.

- If the wear limit is exceeded, repeat the measurement with new valves.
- Renew cylinder head if wear limit is still exceeded.

> **Note**
>
> Valve guides cannot be exchanged.

## 4.2 Checking valves

- Check for scoring on valve stems and valve seat surfaces.
- Exchange valve if significant scoring can be seen.

## 4.3 Valve dimensions

![](https://catalog.polo.blue/manuals/vw-polo-engine-ea211-14-tsi/2c1decda597952e7.webp)

> **Note**
>
> Never rework the inlet and exhaust valves. Only lapping-in is permitted.

| Dimension | Inlet valve | Outlet valve |
| --- | --- | --- |
| ∅ a mm | 28.5 | 25.0 |
| ∅ b mm | 4.973 | 4.963 |
| c mm | 110.25 | 110.09 |
| α ∠° | 45 | 30 |